Testing the RS232 loopback plug
Test the plug by attaching it to the serial port of the Techline computer or into a certified Tech2 USB-2-serial adapter. Download a serial terminal application like RealTerm to diagnose the loop-back functionality.
Now plug your RJ-45 loop-back adapter into the Tech2 device and navigate to the RS-232 test. Depending on the software version there are various options to get to the RS-232 test menu.
While using the (SAAB 44.000 .bin file)[/content/which_.bin-files_are_available/SAAB.html] you need to follow this procedure;
- Insert the loop-back plug into the RJ-45 port
- Press
PWR
to turn on the Tech2 - Title screen, press
ENTER
F2
: Tools OptionsF3
: Field Services DiagnosticsF3
: Selectable Main PCBF2
: RS-232 LoopBack
While using the (SAAB 148.000 .bin file)[/content/which_.bin-files_are_available/SAAB.html] you need to follow this procedure;
- Insert the loop-back plug into the RJ-45 port
- Press
PWR
to turn on the Tech2 - Title screen, press
ENTER
F2
: Tool OptionsF0
: Tech2 Self Test- Press
EXIT
on the notification screen F3
: Selectable Main PCBF2
: RS-232 LoopBack
Now the Tech2 should respond with the following: RS-232 Test: Passed
If the Tech2 responds with RS-232 Test: LoopBack Not Connected
or ADDRESS ERROR - PROCESSOR HALT
the chances are high that the MAX202 or the MAX232 is borked, which means replacing the SMD mountec RS-232 communications chip (SOIC type), noted as U202 on the main PCB.
Reference: The three dudes and their cars…